
Add to Cart
Tattoo removal Q-Switched ND Yag Laser machine / nd yag laser hair removal machine
Treatments:
A. Remove tattoos of all color;
B. Remove spots (freckle,coffee spots,age spots,nevus of ota);
C. Remove lip-line,eye-line,eyebrow,birthmark,skin tags;
D. Skin rejuvenation&skin whitening(1320nm with medical carbon powder)
Advantage:
1. Truly portable, continent
2. New-developed hand piece
3. Infrared ray aiming
4. Water-flow monitor
5. Water flow and temp monitor
6. Plug and play functione and meet the continuously long time work of machine.
Specification
Laser type | Q-Switched ND:YAG |
Cooling manner | Closed-off water circulation + air |
Laser wave length | 1064nm/532nm |
Black moppet wave length | 1320nm |
Single pulse energy | ≤200mj 1064nm |
Spot diameter | 1-5mm |
Pulse width | 10-20ns |
Working frequency | 1-6HZ |
Remove Red Base | 532nm crystal |
Remove Black Base | 1064nm crystal |
Cooperate with carbon Powder,tender & whitening | 1320nm Black Moppet Head |
Application:
Treatment course for different illness case as follows:
Treatments Treatment course required ( cure times) Treatment course interval Remark (requirements in surgery)
eyebrow-embroidery(eyeliner grain), 1 –2 times, 30-60 days, Eyebrow blow, eyeball protection
Eyebrow-embroidery ( eyeliner embroidery), 1-3 times, 45-60 days, Eyebrow blow, eyeball protection
Lip line (red dyed lip), 1-3 times, 15-45 days, Use 532nm filter
Tattoo(caused by extraneous wounds), 1-4 times, 30-60 days, Blood infiltration will be fine on wounds
Freckle, age spot, 1-4 times, 15-30 days, Blood infiltration will be fine on wounds
Birthmark, nevus/mole, 3-7 times, 45-90 days Must have Blood infiltration.
(1) Treatment for tattoo in eyebrow
Customer could not open eyes during treatment, operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatment area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to treatment area, start treatment from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.
(2) Remove eye line
The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and treatment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
Treatment should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.
(3) Remove lip line
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, red and brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal treatment will fail. It should have 45-60 days interval to continue next treatment until remove all.
(4) Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until remove all.
(5) Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all.
(6) Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days interval to continue
What is the treatment Principle?
1. Adopting the Q-Switched ND:YAG model,the equipment uses laser to emit high energy instantaneously which smashing the pigment of pathological tissues,namely the laser leading explosive effect:High energy emits instantaneously,making particular wavelength laser penetrating epidermis and getting into pathological pigment tissues in only 6nms.Then pigments expand in top speed and explode.The superficial epidermis would be bounded out of body;other part of the pigments would split into granules which would be engulfed by macrophages,then exclude by the lymphatic system finally.The pigment becomes shallow gradually finally disappear while the surrounding normal skin tissues keep sound as they do not absorb particular wavelength laser.
How it works
Nd yag Laser tattoo equipment adopts the Q swithch mode, which makes use of the instantaneous emitted
laser to break the pigment in ill structure. That’s the laser instantaneous emit theory: centralized
high energy emit suddenly, which makes laser of settled wave band instantaneously penetrate through
cuticle to the ill structure in 6ns, and break the relevent pigments quickly. After aborb the heat,
the pigments swell and break down, some pigments ( in skin-deep cuticle ) fly off the body immediately,
and other pigments ( deep structure ) break down then become the tiny granule can be licked up
by the cell, digested and egest from the lymph sell. Then the pigments in ill structure lighten to
disappear. Moreover, the laser do not damage the around normal skin.